Filter Results By:

Products

Applications

Manufacturers

Showing results: 76 - 90 of 137 items found.

  • ITA, G10, 10 Module, Removable Backshell, Keying Feature, With Protective Cover

    410104272 - Virginia Panel Corporation

    The G10 ITA is equipped with a removable EMI-shielded cover. The cover slides up to provide access to wires and connectors and is secured by two screws. The removable and adjustable U-shaped cable clamps are attached by screws to the ITA frame and allows ITA modules to be pre-wired before assembly. The clamps can hold cable bundles with an oblong bushing effective diameter of 1.55". ITA strain relief plates are not needed.

  • ITA, G2, 2 Module, Removable Backshell, Keying Feature, With Protective Cover

    410120110 - Virginia Panel Corporation

    The G2 ITA is equipped with a removable EMI-shielded cover. The cover slides up to provide access to wires and connectors and is secured by two screws. The removable and adjustable U-shaped cable clamp is attached by screws to the ITA frame and allows ITA modules to be pre-wired before assembly. The clamp can hold cable bundles with an oblong bushing effective diameter of 1.55". ITA strain relief plates are not needed.

  • True-rms Thermal Multimeter

    279 - Fluke Corporation

    Thermal imaging multimeters are a first-line troubleshooting tool for electrical equipment that can check hot spots on high-voltage equipment and transformers, and detect heating of fuses, wires, insulators, connectors, splices and switches. Scanning with the 279 FC's thermal imager reveals many electrical issues rapidly and from a safe distance. By combining two tools into one, the thermal multimeter lightens the load and increases productivity.

  • EasyView™ Dual Input Thermometers

    Extech EA10 - Extech Instruments Corporation

    EA10 is an EasyView Dual Input Thermometer. Basic Type K Thermometer with wide temperature range. Temperature range from -200 to 1999°F (-200 to 1360°C) with 0.1°/1° resolution. Features Data Hold, Auto power off, low battery and overrange indication. Complete with built-in stand, protective holster, two Type K bead wire temperature probes and batteries.

  • PCI-4070, 6½-Digit, ±300 V, 1.8 MS/s Isolated Digitizer Included, PCI Digital Multimeter Device

    778275-01 - NI

    The PCI‑4070 is a high-performance DMM that provides the measurement capabilities found in two common test instruments: a high-resolution DMM and a digitizer. As a DMM, the PCI‑4070 delivers fast, accurate AC/DC voltage, AC/DC current, 2‑ or 4‑wire resistance, and frequency/period measurements, as well as diode tests. In the high-voltage, isolated digitizer mode, the PCI‑4070 can acquire waveforms at sample rates up to 1.8 MS/s.

  • Cable Testers

    Meilhaus Electronic GmbH

    Passage test:Detects open wires, short circuits and faulty wiring. Pass / fail test using a given pattern cable. Finding intermittent connections.Save cable data for documentation purposes. Print wiring diagrams. Printing labels. Log and print error logs.Graphical representation of the wiring of cables, graphical comparison of two cables. Easy, intuitive, graphical tracking of individual wires of a cable.Quickly install quick-mount boards for a variety of connector types such as BNC, RJ45, Sub-D, flat-ribbon connectors, and many more.Easy connection to the PC via USB .Light Director System:LED-led assembly of connectors. Optional also with voice output. High degree of safety due to fault checking during assembly.

  • NI-9226, 8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module

    783864-02 - NI

    8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module - The NI‑9226 is a resistance temperature detector (RTD) input module. You can configure the NI‑9226 for two sample rate modes: high sample rate or high resolution. The NI‑9226 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3‑ or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per-channel current excitation. The NI‑9226 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.

  • NI-9226, 8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module

    785189-01 - NI

    8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module - The NI‑9226 is a resistance temperature detector (RTD) input module. You can configure the NI‑9226 for two sample rate modes: high sample rate or high resolution. The NI‑9226 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3‑ or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per-channel current excitation. The NI‑9226 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.

  • NI-9216, 8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module

    785186-01 - NI

    8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module - The NI‑9216 is a resistance temperature detector (RTD) input module. You can configure the NI‑9216 for two sample rate modes: high sample rate or high resolution. The NI‑9216 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3-‑or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per channel current excitation. The NI‑9216 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.

  • NI-9216, 8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module

    783863-01 - NI

    8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module - The NI‑9216 is a resistance temperature detector (RTD) input module. You can configure the NI‑9216 for two sample rate modes: high sample rate or high resolution. The NI‑9216 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3-‑or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per channel current excitation. The NI‑9216 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.

  • NI-9217, 4-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module

    779592-01 - NI

    4-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module - The NI‑9217 is a resistance temperature detector (RTD) input module. You can configure the NI‑9217 for two sample rate modes: high sample rate or high resolution. The NI‑9217 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3‑ or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per channel current excitation. The NI‑9217 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.

  • NI-9226, 8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module

    783864-01 - NI

    8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module - The NI‑9226 is a resistance temperature detector (RTD) input module. You can configure the NI‑9226 for two sample rate modes: high sample rate or high resolution. The NI‑9226 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3‑ or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per-channel current excitation. The NI‑9226 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.

  • NI-9216, 8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module

    783863-02 - NI

    8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module - The NI‑9216 is a resistance temperature detector (RTD) input module. You can configure the NI‑9216 for two sample rate modes: high sample rate or high resolution. The NI‑9216 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3-‑or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per channel current excitation. The NI‑9216 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.

  • Open Circuit Locator

    A994 - AGM Elettronica

    The A994 is an open circuit locator for electric and telephone cables wind on the reel; it gives the position of the fault from the inside or outside end of the cable, in percentage to the total cable length. The instrument measures the ratio of the capacitances of the two sections of failed conductor using two high precision i/v converters. The advantage of this method is due to the fact that the measurement error depends almost exclusively on the dimensional inhomogeneity of the cable. The A994 has the unique feature to permit the location of fault in cables with all broken wires. This instrument locates breaks in cables with a total capacity between 2 nF and 5 uF. The distance to fault is displayed on a large LCD display.

  • SparkFun Thermocouple Breakout

    MAX31855K - SparkFun Electronics

    The SparkFun MAX31855K Thermocouple Breakout is a simple 14-bit resolution, SPI-compatible, serial interface thermocouple digitizer that makes reading a wide range of temperatures possible. A thermocouple works by taking two wires made of dissimilar metals, connecting them at the two ends, and making a temperature gradient between one end and the other (a 'hot' end and a 'cold' one). Once this is achieved, a voltage potential is formed and current flows. The SparkFun Thermocouple Breakout takes a standard Type-K thermocouple in one end, digitizes the temperature measured and sends that data out the other end via a SPI interface, thereby interpreting the data and translating it for you to read!

Get Help